MagneMover LITE Tandem Puck Startup Application Note
This application note describes layout concerns and a potential startup failure for MagneMover LITE systems using tandem pucks, caused by the system's inability to definitively differentiate between the gap within a tandem puck and the gap between separate pucks. It provides recommended tandem spacing of 55mm (bracket-to-bracket) or 204mm center-to-center to ensure successful startup, and includes examples of failures on paths with only ¼-Meter or Curve Motors.