Safety Chain with Magnetic Switches Application Guide
AI-enhanced description
This document describes a safety chain solution using magnetic switches to implement a safety-related stop function for movable guards protecting hazardous areas, achieving Performance Level e (PL e) and SIL 3. It details the design with redundant contacts and contactors, monitoring for failures like contact welding, and typical applications in compact machinery with frequent access.