56% (100)
•
1.7k views
•
3 pages
DCS800 Drive Digital Output Toggle Based on Analog Input Application Note
AI-enhanced description
This application note describes how to toggle or change the state of a digital output on an ABB DCS800 drive based on the voltage value of an analog input. It provides a specific example of energizing Digital Output 4 when Analog Input 1 is below 1 volt, using Compare and BSET function blocks in DriveAP code.